<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Precise Calibration &#187; Products</title>
	<atom:link href="http://www.precisecalibration.co.uk/test-equipment/feed/?product_cat=power-quality-analysers-hire-equipment" rel="self" type="application/rss+xml" />
	<link>http://www.precisecalibration.co.uk</link>
	<description></description>
	<lastBuildDate>Thu, 31 Oct 2024 14:05:56 +0000</lastBuildDate>
	<language>en-US</language>
		<sy:updatePeriod>hourly</sy:updatePeriod>
		<sy:updateFrequency>1</sy:updateFrequency>
	<generator>https://wordpress.org/?v=3.8.41</generator>
	<item>
		<title>Chauvin Arnoux CA8230</title>
		<link>http://www.precisecalibration.co.uk/product/chauvin-arnoux-ca8230/</link>
		<comments>http://www.precisecalibration.co.uk/product/chauvin-arnoux-ca8230/#comments</comments>
		<pubDate>Tue, 12 Nov 2019 13:51:16 +0000</pubDate>
		<dc:creator><![CDATA[Noel Harrison]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisecalibration.co.uk/product/chauvin-arnoux-ca8230/</guid>
		<description><![CDATA[]]></description>
				<content:encoded><![CDATA[]]></content:encoded>
			<wfw:commentRss>http://www.precisecalibration.co.uk/product/chauvin-arnoux-ca8230/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Chauvin Arnoux CA8334</title>
		<link>http://www.precisecalibration.co.uk/product/chauvin-arnoux-ca8334/</link>
		<comments>http://www.precisecalibration.co.uk/product/chauvin-arnoux-ca8334/#comments</comments>
		<pubDate>Tue, 12 Nov 2019 13:50:50 +0000</pubDate>
		<dc:creator><![CDATA[Noel Harrison]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisecalibration.co.uk/?post_type=product&#038;p=1428</guid>
		<description><![CDATA[]]></description>
				<content:encoded><![CDATA[]]></content:encoded>
			<wfw:commentRss>http://www.precisecalibration.co.uk/product/chauvin-arnoux-ca8334/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Chauvin Arnoux CA8334B</title>
		<link>http://www.precisecalibration.co.uk/product/chauvin-arnoux-ca8334b/</link>
		<comments>http://www.precisecalibration.co.uk/product/chauvin-arnoux-ca8334b/#comments</comments>
		<pubDate>Tue, 12 Nov 2019 13:50:57 +0000</pubDate>
		<dc:creator><![CDATA[Noel Harrison]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisecalibration.co.uk/product/chauvin-arnoux-ca8334b/</guid>
		<description><![CDATA[]]></description>
				<content:encoded><![CDATA[]]></content:encoded>
			<wfw:commentRss>http://www.precisecalibration.co.uk/product/chauvin-arnoux-ca8334b/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Kyoritsu KEW6310 Power Quality Analyser</title>
		<link>http://www.precisecalibration.co.uk/product/kyoritsu-kew6310-power-quality-analyser/</link>
		<comments>http://www.precisecalibration.co.uk/product/kyoritsu-kew6310-power-quality-analyser/#comments</comments>
		<pubDate>Tue, 12 Nov 2019 14:29:31 +0000</pubDate>
		<dc:creator><![CDATA[Noel Harrison]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisecalibration.co.uk/?post_type=product&#038;p=1457</guid>
		<description><![CDATA[]]></description>
				<content:encoded><![CDATA[]]></content:encoded>
			<wfw:commentRss>http://www.precisecalibration.co.uk/product/kyoritsu-kew6310-power-quality-analyser/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Power Quality Health Check</title>
		<link>http://www.precisecalibration.co.uk/product/power-quality-health-check/</link>
		<comments>http://www.precisecalibration.co.uk/product/power-quality-health-check/#comments</comments>
		<pubDate>Tue, 10 Jul 2018 09:57:34 +0000</pubDate>
		<dc:creator><![CDATA[Noel Harrison]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisecalibration.co.uk/?post_type=product&#038;p=364</guid>
		<description><![CDATA[Power Quality Health Check provides an online service to produce an intuitive Power Quality Survey Report provided by Power Quality Expert.  The data you have recorded from your power quality analyser or energy logger is used to present the results in an easy to understand format. Additional comments and basic analysis is also included in [&#8230;]]]></description>
				<content:encoded><![CDATA[<p><a title="Power Quality Health Check" href="https://powerqualityhealthcheck.com" target="_blank">Power Quality Health Check</a> provides an online service to produce an intuitive Power Quality Survey Report provided by <a href="http://www.powerqualityexpert.com" target="_blank" rel="noopener">Power Quality Expert</a>.  The data you have recorded from your power quality analyser or energy logger is used to present the results in an easy to understand format. Additional comments and basic analysis is also included in the report where we identify areas of interest.</p>
<p>Simply upload your file directly to us through the online portal.  Once the report is ready, login through your personal account and view online or download in PDF whenever you are ready.  A unique URL link is also generated to allow you to share the report with other members of your team or directly to your customers.</p>
<p>All file types are supported from popular power quality analysers and energy loggers including Sonel, Fluke, Elcomponent, Metrel, Chauvin Arnoux and many more.  Contact us today to check the compatibility of your Power Energy Logger or Power Quality Analyser or if you need to hire a meter for your next power quality survey.</p>
<p><a href="http://www.precisecalibration.co.uk/wp-content/uploads/2019/11/Power-Quality-Health-Check-Datasheet.pdf" target="_blank">View Power Quality Health Check Datasheet</a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.precisecalibration.co.uk/product/power-quality-health-check/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Sonel PQM-700</title>
		<link>http://www.precisecalibration.co.uk/product/sonel-pqm-700/</link>
		<comments>http://www.precisecalibration.co.uk/product/sonel-pqm-700/#comments</comments>
		<pubDate>Tue, 10 Jul 2018 10:01:52 +0000</pubDate>
		<dc:creator><![CDATA[Noel Harrison]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisecalibration.co.uk/?post_type=product&#038;p=365</guid>
		<description><![CDATA[Description Analyser measures and records according to the IEC 61000-4-30 CLASS S STANDARD. Features: Power to the analyser is supplied from tested mains (internal power supply) and is used in all types of networks from 64 V to 760 V, with particular emphasis on measurements at low voltage poles, due to the ease of connection, [&#8230;]]]></description>
				<content:encoded><![CDATA[<div id="tab-description" role="tabpanel">
<div>
<h3>Description</h3>
<div>
<div>
<div>
<div>
<p><strong>Analyser measures and records according to the IEC 61000-4-30 CLASS S STANDARD.</strong></p>
<p>Features:</p>
<ul>
<li>Power to the analyser is supplied from tested mains (internal power supply) and is used in all types of networks from 64 V to 760 V, with particular emphasis on measurements at low voltage poles, due to the ease of connection,</li>
<li>Has an independent power supply socket, especially suited for voltage measurements for transformers and DC circuits,</li>
<li>Built-in real-time clock.</li>
</ul>
<p>Possible measurements:</p>
<ul>
<li>Measurements according to EN 50160,</li>
<li>Voltage L1, L2, L3,<br />
– average, minimum, maximum and instantaneous values, range to 760 V, ability to work with voltage transformers,</li>
<li>Current L1, L2, L3, N (four inputs),<br />
– average, minimum, maximum and instantaneous values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers,</li>
<li>Crest factor for voltage and current,</li>
<li>Frequency from 40 Hz to 70 Hz ,</li>
<li>Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),</li>
<li>Power recording:<br />
– Budeanu method,<br />
– IEEE 1459,</li>
<li>Active, reactive, apparent energy,</li>
<li>Power factor, cosÏ†, tgÏ†,</li>
<li>Up to 40th harmonics for voltage and current,</li>
<li>Total Harmonic Distortion (THD) for voltage and current,</li>
<li>Short-term (PST) and long-term (PLT) flicker,</li>
<li>Unbalance of voltage and current,</li>
<li>Current and voltage events registration including waveforms and RMS graphs half period.</li>
</ul>
<p><strong><a href="http://powerqualityexpert.com/wp-content/uploads/2016/12/datasheet_pqm-700_v1_en.pdf" target="_blank">Download Datasheet PQM-700</a></strong></p>
</div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
			<wfw:commentRss>http://www.precisecalibration.co.uk/product/sonel-pqm-700/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Sonel PQM-703</title>
		<link>http://www.precisecalibration.co.uk/product/sonel-pqm-703/</link>
		<comments>http://www.precisecalibration.co.uk/product/sonel-pqm-703/#comments</comments>
		<pubDate>Tue, 10 Jul 2018 10:05:02 +0000</pubDate>
		<dc:creator><![CDATA[Noel Harrison]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisecalibration.co.uk/?post_type=product&#038;p=367</guid>
		<description><![CDATA[Description Possible measurements: Measurements according to EN 50160 Measures and Records According to the IEX 61000-4-30 Standard Class A Active, reactive, apparent energy. Power factor. Harmonics for voltage and current. Total Harmonic Distortion (THD) for voltage and current. Short-term (P ) and long-term (P ) flicker, Unbalance of voltage and current. Current events detection including [&#8230;]]]></description>
				<content:encoded><![CDATA[<div id="tab-description" role="tabpanel">
<div>
<h3>Description</h3>
<p>Possible measurements:</p>
<ul>
<li>Measurements according to EN 50160</li>
<li>Measures and Records According to the IEX 61000-4-30 Standard Class A</li>
<li>Active, reactive, apparent energy.</li>
<li>Power factor.</li>
<li>Harmonics for voltage and current.</li>
<li>Total Harmonic Distortion (THD) for voltage and current.</li>
<li>Short-term (P ) and long-term (P ) flicker,</li>
<li>Unbalance of voltage and current.</li>
<li>Current events detection including waveforms recording.</li>
<li>Current and voltage events recording with waveforms (up to 1s) and RMS 10 ms graphs with 30 s maximum recording time.</li>
<li>Current and voltage waveforms recording after each averaging period.</li>
<li>Voltage L1, L2, L3, N PE – average, minimum, maximum and instantaneous , to 760 V, ability to work with voltage transformers.</li>
<li>Current L1, L2, L3, N (four inputs) – average, minimum, maximum and instantaneous values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers.</li>
<li>Frequency from 40 Hz to 70 Hz.</li>
<li>Active, apparent power, the type of reactive power (capacitive, inductive)</li>
<li>Mains signaling up to 3000 Hz.</li>
<li>Transients up to ±6000 V with max. sampling frequency 10 MHz. Minimal transient time is 650 ns.</li>
</ul>
<p><a href="http://powerqualityexpert.com/wp-content/uploads/2016/12/datasheet_pqm-702_703_v6_en.pdf" target="_blank">Download Datasheet PQM-703</a></p>