<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Precise Calibration &#187; Products</title>
	<atom:link href="http://www.precisecalibration.co.uk/test-equipment/feed/?product_cat=insulation-testers-5kv" rel="self" type="application/rss+xml" />
	<link>http://www.precisecalibration.co.uk</link>
	<description></description>
	<lastBuildDate>Thu, 31 Oct 2024 14:05:56 +0000</lastBuildDate>
	<language>en-US</language>
		<sy:updatePeriod>hourly</sy:updatePeriod>
		<sy:updateFrequency>1</sy:updateFrequency>
	<generator>https://wordpress.org/?v=3.8.41</generator>
	<item>
		<title>Sonel MIC-5005</title>
		<link>http://www.precisecalibration.co.uk/product/sonel-mic-5005/</link>
		<comments>http://www.precisecalibration.co.uk/product/sonel-mic-5005/#comments</comments>
		<pubDate>Tue, 10 Jul 2018 11:11:39 +0000</pubDate>
		<dc:creator><![CDATA[Noel Harrison]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisecalibration.co.uk/?post_type=product&#038;p=393</guid>
		<description><![CDATA[Description Insulation resistance measurement up to 15T Ohm in Accordance with IEC 61557-2 Test Voltages 50V…1000 V at 10 V and 1000V…5000 V at 25 V resolution. Continuous indication of measured insulation resistance or leakage current. Automatic discharge of measured object capacitance voltage after the end of insulation resistance measurement. Acoustic signaling of 5 seconds [&#8230;]]]></description>
				<content:encoded><![CDATA[<div id="tab-description" role="tabpanel">
<div>
<h3>Description</h3>
<p>Insulation resistance measurement up to 15T Ohm in Accordance with IEC 61557-2</p>
<p>Test Voltages 50V…1000 V at 10 V and 1000V…5000 V at 25 V resolution.</p>
<p>Continuous indication of measured insulation resistance or leakage current.</p>
<ul>
<li>Automatic discharge of measured object capacitance voltage after the end of insulation resistance measurement.</li>
<li>Acoustic signaling of 5 seconds intervals to facilitate capturing time characteristics.</li>
<li>Metered T , T and T test times for measuring one or two absorption coefficients from the range of 1…600 s.</li>
<li>Adjustable measuring time to 99’59’’.</li>
<li>Polarization index (PI) and dielectric absorption ratio (DAR) measurement.</li>
<li>Indication of actual test voltage during measurement.</li>
<li>1.2 mA and 3 mA test current.</li>
<li>Step voltage insulation resistance measurement (SV)</li>
<li>Dielectric Discharge calculation (DD)</li>
<li>Protection against measuring live objects.</li>
<li>Measurements with test leads up to 20 m.</li>
<li>Digital filters function for measurements in high noise enviroment (10 s, 30 s, 60 s)</li>
<li>Measurement of leakage current during insulation resistance testing.</li>
<li>Measurement of capacitance during the measurement of RISO.</li>
<li>DC and AC voltage measurement in the range of 0…600 V.</li>
<li>Memory.</li>
<li>Power supply from main power line or battery packs, low battery warning indicator, built-in fast charger.</li>
<li>Display backlit.</li>
<li>The instruments meet the requirements of the EN 61557 standard.</li>
</ul>
<p><a href="http://powerqualityexpert.com/wp-content/uploads/2016/12/datasheet_mic-5005_5010_en_v2.2.pdf" target="_blank">Download Datasheet MIC-5005</a></p>
</div>
</div>
]]></content:encoded>
			<wfw:commentRss>http://www.precisecalibration.co.uk/product/sonel-mic-5005/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Sonel MIC-5010</title>
		<link>http://www.precisecalibration.co.uk/product/sonel-mic-5010/</link>
		<comments>http://www.precisecalibration.co.uk/product/sonel-mic-5010/#comments</comments>
		<pubDate>Tue, 10 Jul 2018 11:14:32 +0000</pubDate>
		<dc:creator><![CDATA[Noel Harrison]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisecalibration.co.uk/?post_type=product&#038;p=394</guid>
		<description><![CDATA[Description Insulation resistance measurement up to 15T Ohm in Accordance with IEC 61557-2. Test Voltages 50V…1000 V at 10 V and 1000V…5000 V at 25 V resolution. Continuous indication of measured insulation resistance or leakage current. Automatic discharge of measured object capacitance voltage after the end of insulation resistance measurement. Acoustic signaling of 5 seconds [&#8230;]]]></description>
				<content:encoded><![CDATA[<div id="tab-description" role="tabpanel">
<div>
<h3>Description</h3>
<p>Insulation resistance measurement up to 15T Ohm in Accordance with IEC 61557-2.</p>
<p>Test Voltages 50V…1000 V at 10 V and 1000V…5000 V at 25 V resolution.</p>
<p>Continuous indication of measured insulation resistance or leakage current.</p>
<ul>
<li>Automatic discharge of measured object capacitance voltage after the end of insulation resistance measurement.</li>
<li>Acoustic signaling of 5 seconds intervals to facilitate capturing time characteristics.</li>
<li>Metered T , T and T test times for measuring one or two absorption coefficients from the range of 1…600 s.</li>
<li>Adjustable measuring time to 99’59’’.</li>
<li>Polarization index (PI) and dielectric absorption ratio (DAR) measurement.</li>
<li>Indication of actual test voltage during measurement.</li>
<li>1.2 mA and 3 mA test current.</li>
<li>Step voltage insulation resistance measurement (SV)</li>
<li>Dielectric Discharge calculation (DD)</li>
<li>Protection against measuring live objects.</li>
<li>Measurements with test leads up to 20 m.</li>
<li>Digital filters function for measurements in high noise enviroment (10 s, 30 s, 60 s)</li>
<li>Continuity measurement of protective connections and equipotential bonding in accordance with EN 61557-4 with current &gt; 200 mA.</li>
<li>Adjustable limits for measured resistance R and RISO CONT.</li>
<li>Measurement of leakage current during insulation resistance testing.</li>
<li>Measurement of capacitance during the measurement of RISO.</li>
<li>DC and AC voltage measurement in the range of 0…600 V.</li>
<li>Memory.</li>
<li>Power supply from main power line or battery packs, low battery warning indicator, built-in fast charger.</li>
<li>Keyboard and display backlit.</li>
<li>The instruments meet the requirements of the EN 61557 standard.</li>
</ul>
<p><a href="http://powerqualityexpert.com/wp-content/uploads/2016/12/datasheet_mic-5005_5010_en_v2.2.pdf" target="_blank">Download Datasheet MIC-5010</a></p>
</div>
</div>
]]></content:encoded>
			<wfw:commentRss>http://www.precisecalibration.co.uk/product/sonel-mic-5010/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Sonel MIC-5050</title>
		<link>http://www.precisecalibration.co.uk/product/sonel-mic-5050/</link>
		<comments>http://www.precisecalibration.co.uk/product/sonel-mic-5050/#comments</comments>
		<pubDate>Tue, 10 Jul 2018 11:15:29 +0000</pubDate>
		<dc:creator><![CDATA[Noel Harrison]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisecalibration.co.uk/?post_type=product&#038;p=395</guid>
		<description><![CDATA[Description Insulation resistance measurement up to 20 TΩ. Measurement voltage any in the range of 50…5000 V (50…1000 V at 10 V and 1…5 kV at 25 V) Digital filters function for measurements in high noise environment. Continuity measurement of protective connections and equipotential bonding in accordance with EN 61557-4 with current &#62; 200 mA. [&#8230;]]]></description>
				<content:encoded><![CDATA[<div id="tab-description" role="tabpanel">
<div>
<h3>Description</h3>
<p>Insulation resistance measurement up to 20 TΩ.</p>
<p>Measurement voltage any in the range of 50…5000 V (50…1000 V at 10 V and 1…5 kV at 25 V)</p>
<ul>
<li>Digital filters function for measurements in high noise environment.</li>
<li>Continuity measurement of protective connections and equipotential bonding in accordance with EN 61557-4 with current &gt; 200 mA.</li>
<li>Adjustable limits for measured resistance R and R , ISO CONT.</li>
<li>Measurement of leakage current during insulation resistance testing.</li>
<li>DC and AC voltage measurement in the range of 0…750 V.</li>
<li>Drawing graphs on the display during measurement.</li>
<li>Innovative memory with possibility of description of: measurement points, facilities, names of customers.</li>
<li>Operating with mini Bluetooth keyboard (option)</li>
<li>Graphic LCD 5,6’’ backlit.</li>
<li>Keyboard backlit.</li>
<li>Power supply from main power line or battery packs.</li>
<li>Built-in fast charger.</li>
<li>The instruments meet the requirements of the EN 61557 standard.</li>
</ul>